(1) Rotational Sensor Adjustment
Distance Adjustment;
Pull the rotational sensor as far away from the basket (tumbler) as possible.
Spin/rotate the basket (tumbler) until the target (target lines up behind one of the basket ribs)
is aligned with the rotational sensor.
Mark basket (tumbler) rib with tape.
The rotational sensor
has to be adjusted towards
the target until there is a 3/16" gap.
Time Adjustment;
Jog basket (tumbler) for 10-seconds.
Time the rotational sensor (the
time is measured from the last
time the target (tapered rib) goes
by the rotational sensor and the indicator light
on the sensor goes out.
The measured time
has to be 12-seconds.
If an adjustment is required, remove the adjustment cap on the proximity sensor.
Turn potentiometer on the proximity sensor
Retime the sensor.
Adjust as needed.
11) Reinstall the left tilt guard removed in Step #3 (refer to previous page [page 39]).
12) Reinstall the tumbler (basket) section bottom left hand panel removed in Step #2 (refer to previous
page [page 39]).