0

Out of 0 Ratings

Owner's of the ADC Clothes Dryer AD-464 gave it a score of 0 out of 5. Here's how the scores stacked up:
  • Reliability

    0 out of 5
  • Durability

    0 out of 5
  • Maintenance

    0 out of 5
  • Performance

    0 out of 5
  • Ease of Use

    0 out of 5
of 96
 
23
1.
Safety Devices Locations/Functions/Messages
S
AFETY
D
EVICES
L
OCATION
F
UNCTION
C
OMPUTER
D
ISPLAY
M
ESSAGE
R
ESULT OF
T
RIPPING
Load Door Switch
Left side of
Load door
Ensures dryer load doors
are closed
"DOOR OPEN" Dryer will not run
Unload door switch (Two
door unit only)
Right side of
unload door
Ensures dryer unload
doors are closed
"DOOR OPEN" D
RYER
W
ILL
N
OT
R
UN
Tilting Switches
Top left side of
base module
Ensures dryer is level "LEVEL FAULT" D
RYER
W
ILL
N
OT
R
UN
Drum Rotation Sensor
Left side of
tumbler section
Ensures tumbler is
rotating
"DRUM FAULT" S
TOPS
H
EAT
O
NLY
Lint Chamber air pressure
switch
Rear of base
module
Ensures proper air flow
through dryer
"AIRFLOW FAULT" S
TOPS
H
EAT
O
NLY
Burner Fan Air Flow
Switch
(Gas Dryers Only)
Center of heat
console
Ensures proper
combustion air flow into
the burner box
"HEATER FAULT" S
TOPS
H
EAT
O
NLY
Hi/Lo Gas Pressure
Switch
(Gas Dryers Only)
Lower left of
heat console
section
Ensures proper gas
supply pressure for
adequate ignition
"GAS SUPPLY
FAULT"
S
TOPS
H
EAT
O
NLY
Heat Reclaimer Damper
Switch
Right side of
heat console
Ensures that the heat
reclaimer is either
opened or closed
Input L.E.D. #13 of
the PLC is off
N
ONE
Heat Console Door
Access Door Switch
Inside heat
console
Ensures that access doors
are closed
"DOOR OPEN" D
RYER
W
ILL
N
OT
R
UN
Exhaust Air Temp Control
Sensor
Inside burner
section duct
Monitors tumbler exhaust
air temp
"EXHAUST DSFL" S
TOPS
H
EAT
O
NLY
Exhaust Air Hi Temp
Control Sensor
Inside exhaust
duct
Monitors tumbler exhaust
and air temp
"HI-TEMP FAULT" S
TOPS
H
EAT
O
NLY
Intake Air Temp Control
Sensor (optional)
Top right of
tumbler section
Monitors tumbler air
intake temp
"INTAKE DSFL" S
TOPS
H
EAT
O
NLY
Intake Air Temp Control
Sensor
Top right of
tumbler section
Monitors tumbler air
intake temp
"HI-TEMP FAULT" S
TOPS
H
EAT
O
NLY
Burner Hi-Limit Safety
Sensor
Top of burner
section
Monitors air temp above
the burner box
"HI-TEMP FAULT" S
TOPS
H
EAT
O
NLY
Sprinkler Control Safety
Sensor
Top right of
tumbler section
Open sprinkler system
water valve on hi-temp
condition
Orange sprinkler
pilot light comes on.
Alarm horn sounds.
O
PENS
T
HE
S
PINKLER
W
ATER
V
ALVE
AND
P
OWER
D
OWN
T
HE
W
HOLE
D
RYER
Lint Drawer Switches
Above lint
drawer handles
Disables machine when
drawers are open or if
drawers have not been
cleaned in last five load
Lint Drawer D
RYER
W
ILL
N
OT
R
UN