of 204
 
Send document comments to nexus7k-docfeedback@cisco.com
6-33
Cisco Nexus 7000 Series Hardware Installation and Reference Guide
OL-18634-01
Chapter 6 Managing the Device Hardware
EPLD Configuration
Mod Ports Module-Type Model Status
--- ----- -------------------------------- ------------------ ------------
1 48 10/100/1000 Mbps Ethernet Module N7K-N148GT-11 ok
3 32 10 Gbps Ethernet Module N7K-M132XP-12 ok
5 0 Supervisor module-1X N7K-SUP1 active
6 0 Supervisor module-1X N7K-SUP1 ha-standby
10 48 10/100/1000 Mbps Ethernet Module N7K-M148GT-11 ok
Mod Sw Hw World-Wide_name(s) (WWN)
--- -------------- ------ -------------------------------------------------
1 4.0(2) 0.503 --
3 4.0(2) 0.601 --
5 4.0(2) 0.900 --
6 4.0(2) 0.802 --
10 4.0(2) 0.902 --
Mod MAC-Address(es) Serial-Num
--- -------------------------------------- ----------
1 00-19-07-6c-c0-6c to 00-19-07-6c-c0-a0 JAB11060144
3 00-1b-54-c1-33-98 to 00-1b-54-c1-33-bc JAB1152010K
5 00-1b-54-c1-16-18 to 00-1b-54-c1-16-20 JAB114902HF
6 00-19-07-c1-00-b8 to 00-1b-54-c1-00-c0 JAB114402JX
10 00-1b-54-c1-07-88 to 00-1b-54-c1-07-bc JAB114501RW
* this terminal session
switch#
Step 2 Install the EPLDs by entering the install module slot_number epld url command.
switch# install module 6 epld bootflash:n7000-s1-epld.4.0.2.img
EPLD image file , built on Fri May 16 20:36:39 2008
EPLD Curr Ver New Ver
-------------------------------------------------------
Power Manager 3.4 3.6
IO 3.23 3.23
Inband 1.7 1.7
Local Bus CPLD 2.1 2.1
CMP CPLD 6.0 6.0
WARNING: Upgrade process could take upto 30 minutes.
Standby supervisor is being upgraded.
Do you want to continue (y/n) ?
Step 3 Begin upgrading the EPLD images by entering Y for yes.
Do you want to continue (y/n) ? Y
Step 4 For releases 4.0(2) or earlier, if you updated the power management EPLD image, you must reset the
power for the module so that EPLD can take effect (this is not required for release 4.0(3) or later). You
can reset the power in one of the following two ways:
To reset the power for the module, physically remove the module and reinstall it.
Note A module reload or just pressing the ejector buttons on the module is not sufficient for this
reset requirement.
To reset the entire system, power cycle the system.