0

Out of 0 Ratings

Owner's of the ACS Clothes Dryer ACS Clothes Dryer gave it a score of 0 out of 5. Here's how the scores stacked up:
  • Reliability

    0 out of 5
  • Durability

    0 out of 5
  • Maintenance

    0 out of 5
  • Performance

    0 out of 5
  • Ease of Use

    0 out of 5
of 51
 
15, 30, & 60 cfm Compact Dryers Chapter 4: Operation 26 of 51
Restoring the Process Air Temperature Controller (E5CN) to Factory Settings
If the preset parameters on the controller have been tampered with and it no longer properly
controls temperature and displays dew point, you can restore the controllers to the factory
setup. Call the Service Department for detailed instructions.
E5CN Operating Parameters
The E5CN controller has several mode selections. Within each mode are numerous
parameters that can be set.
The factory has set the security level to protect the critical parameters from being accidentally
changed. Below is an explanation of the operating modes you will have access to and on the
following page are the manufacturers’ default settings.
Available E5CN Modes
Operation Level
Indicator
Name
Description
Run/Stop Mode
(r-S)
When “RUN” is selected, the control is running.
When “STOP” is selected, the control is stopped.
When the control is stopped, the STOP display
lights. The default is set to “RUN.”
Alarm Value 1
Mode (AL-1)
This setting is used to indicate how many degrees
the process temperature will be allowed to exceed
the set point temperature. An alarm output will de-
energize the heaters.