OPTIONAL MANUAL BYPASS
Provisions are made in the dryer S.A.F.E. system for the installation of an optional manual bypass. Depending
on the model dryer, the connections for the manual bypass are made at the “T” or “three way” fitting, located in
the outlet supply side of the water solenoid valve. The use and connections of this manual bypass are at the
option or discretion of the owner.
The water connection for the manual bypass is made to the “T” or “three way” fitting, which has a 3/8” F.P.T.
and a coupling must be used to provide the minimum 1/2” supply (feed) line.
If the rear area of the dryer, or the water supply is located in an area where it
will be exposed to cold/freezing
temperatures, provisions must be made to protect these water lines from freezing.
WARNING: If the water in the supply line or water solenoid valve freezes, the S.A.F.E. system will
be INOPERATIVE!!
The manual ball cock shutoff valve must be located outside of the dryer at a distance from the dryer where it
is easily accessible.
3. Electrical Requirements
No independent external power source or supply connection is necessary. The 24 volt power to operate the
S.A.F.E. system is accomplished internally in the dryer (from the dryer controls).
WARNING: Electrical power must be provided to the dryer at ALL times. If the main electrical
power supply to the dryer is disconnected, the S.A.F.E. system is INOPERATIVE!!