4.3

Out of 2 Ratings

Owner's of the ADC Clothes Dryer AD-170SE gave it a score of 4.3 out of 5. Here's how the scores stacked up:
  • Reliability

    4.0 out of 5
  • Durability

    4.5 out of 5
  • Maintenance

    4.5 out of 5
  • Performance

    4.5 out of 5
  • Ease of Use

    4.0 out of 5
of 58
 
14
D. FRESH AIR SUPPLY REQUIREMENTS
When the dryer is operating, it draws in room air, heats it, passes this air through the basket (tumbler), and
exhausts it out of the building. Therefore, the room air must be continually replenished from the outdoors. If the
make-up air is inadequate, drying time and drying efficiency
will be adversely affected. Ignition problems and
sail switch “fluttering” problems may result, as well as premature motor failure from overheating. The dryer
must be installed with provisions for adequate combustion and make-up air supply.
Air supply (make-up air) must be given careful consideration to assure proper performance of each dryer. An
unrestricted source of air is necessary for each dryer. An airflow of 3,700 cfm (cubic feet per minute [104.77
cmm] [cubic meters per minute]) must be supplied to each gas dryer and 4,400 cfm (124.59 cmm) must be
supplied to each steam dryer. As a general rule, an unrestricted air entrance from the outdoors (atmosphere) of
a minimum of 4 square feet (0.37 square meters) is required for each gas dryer and a minimum of 4.75 square
feet (0.44 square meters) for each steam dryer.
To compensate for the use of registers or louvers used over the openings, this make-up air must be increased by
approximately thirty-three percent (33%). Make-up air openings should not be located in an area directly near
where exhaust vents exit the building.
It is not necessary to have a separate make-up air opening for each dryer. Common make-up air openings are
acceptable. However, they must be set up in such a manner that the make-up air is distributed equally to ALL
the dryers.
EXAMPLE: For a bank of six (6) dryers, 2 unrestricted openings measuring 3 feet by 4 feet (12 square feet
[0.91 meters by 1.22 meters] [1.11 square meters]) are acceptable.
Allowances must be made for remote or constricting passageways or where dryers are located at excessive
altitudes or predominantly low pressure areas.
IMPORTANT: Make-up air must be provided from a source free of dry cleaning solvent fumes.
Make-up air that is contaminated by dry cleaning solvent fumes will result in
irreparable damage to the motors and other dryer components.
NOTE: Component failure due to dry cleaning solvent fumes will VOID THE WARRANTY.