2.7

Out of 3 Ratings

Owner's of the ADC Clothes Dryer AD-200 gave it a score of 2.7 out of 5. Here's how the scores stacked up:
  • Reliability

    2.0 out of 5
  • Durability

    3.0 out of 5
  • Maintenance

    2.67 out of 5
  • Performance

    3.0 out of 5
  • Ease of Use

    3.0 out of 5
of 106
 
10
EVERY 6 MONTHS
Change gear oil in basket (tumbler) shaft gear (speed) reducer.
1. Remove the drain plug (located at the bottom rear of the reducer).
2. After oil is completely drained, replace the drain plug.
3. Remove the vent plug and pour in 1.4 liters of Mobil Oil DTE HH5G (I.S.O. viscosity grade 460), SAE 90,
or its equivalent.
C. ADJUSTMENTS
7 DAYS AFTER INSTALLATION AND EVERY 6 MONTHS THEREAFTER
Inspect bolts, nuts, screws, (bearing setscrews), grounding connecitons, and nonpermanent gas connections
(unions, shutoff valves, and orifices). Fan (squirrel cage fan) V-belts, along with the motor and drive belts should
be examined and replaced if necessary. Tighten loose V-belts when necessary. Complete operational check of
controls and valves. Complete operational check of ALL safety devices (i.e., door switches, lint drawer switch,
sail switch, burner, and hi-limit thermostats).