0

Out of 0 Ratings

Owner's of the ADC Clothes Dryer Gas Electric Steam gave it a score of 0 out of 5. Here's how the scores stacked up:
  • Reliability

    0 out of 5
  • Durability

    0 out of 5
  • Maintenance

    0 out of 5
  • Performance

    0 out of 5
  • Ease of Use

    0 out of 5
of 66
 
5
TIME FOR AMOUNT TO START
This program retains the time the owner wishes to vend. The feature allows any additional purchase that is
made to be calculated to the second. There is no calculation necessary by the owner. The Phase 5 coin
microprocessor controller (computer) calculates the vended time.
ACCUMULATIVE COIN
This program selection requires that a specific value of coin(s) be inserted for additional time, programmable for
any minimum amount.
COIN COUNT
The number of coins inserted, including a separate display program for optional dual coin acceptors, can be
viewed through the Phase 5 computer’s light emitting diode (L.E.D.) display.
BAD COIN LOCKOUT
Each coin is monitored. Should someone tamper with the coin acceptor or attempt to insert a foreign object, the
microprocessor controller (computer) will “LOCKOUT” and will not accept any entries until the reset time has
elapsed (approximately 15-seconds). Once the reset time has expired, the microprocessor controller (computer)
will automatically reset itself for the next coin entry.
TEMPERATURE CONVERSION
When the temperature conversion status is changed (i.e. from °F to °C), the Phase 5 coin microprocessor
controller (computer) will automatically convert ALL temperature related programs/parameters from Fahrenheit
to Celsius and vice versa. The Phase 5 coin microprocessor controller (computer) will perform this conversion
within 1° F (2° C). The programs affected are:
1. Temperature Display Mode
2. Temperature Selections
3. Cool Down Temperatures
DRYING TEMPERATURES
Any of the three (3) temperature selections (HI/LO/PP) are programmable from a minimum of 100° F to a
maximum of 190° F in ten-degree increments or from a minimum of 38° C to a maximum of 88° C in five-degree
increments. Actual temperature programs are displayed at time of programming for verification.
For the AD-26 and AD-295 any three (3) of the selections (HI/LO/PP) are programmable from a minimum of
100° F to a maximum of 170° F in ten-degree increments, or from a minimum of 38° C to a maximum of 77° C
in five-degree increments.
For the AD-540 and WDA-540 any three (3) of the selections (HI/LO/PP) are programmable from a minimum
of 100° F to a maximum of 160° F in ten-degree increments or from a minimum of 38° C to a maximum of 71°
C in five-degree increments.